Heat Shrinkable Cable Accessories
Features
1. The cross-linked cable thermal shrinkable termination uses the double-earthing technology, in which the
steel armour earthing separates from the copper shield earthing, so that the cable trial is more reasonable.
A. Test the steel armour earthing and earth resistance, if it is conducted, it means the cable protection surface
is damaged.
B. Test the resistance between two earthings, if it is conducted, it means the external sheath is damaged;
test the earth resistance of copper shield earthing, if it is conducted, it means both the internal and external
protection surfaces are damaged.
C. The phase will never fade.
D. The triangular prick is developed for the purpose of convenient operation.
E. The taper-shaped fingertip will never be cracked.
2. The cross-linked cable heat shrinkable cable joint uses the new technology (three-seal technology).
A. The breakdown of cable intermediary joint is caused by poor seal, so our company adopts the new
technology to make the cable operate more safely and conveniently. The three-seal refers to the external
protection seal, internal protection seal, and the seal between two ends of insulation tube.
B. The insulation tube is prolonged to solve the problem of power seize.
C. The protection tube is very soft and shrink fastly.
Specifications
Model |
Name |
Applicable cable section mm2 |
10kv HRYN-1/1 | 10kV cross-linked cable heat shrinkable indoor termination (single-conductor) |
25-50 |
10kv HRYN-1/2 |
70-120 |
|
10kv HRYN-1/3 |
150-240 |
|
10kv HRYN-1/4 |
300-400 |
|
10kv HRYW-1/1 | 10kV cross-linked cable heat shrinkable outdoor termination (single-conductor) |
25-50 |
10kv HRYW-1/2 |
70-120 |
|
10kv HRYW-1/3 |
150-240 |
|
10kv HRYW-1/4 |
300-400 |
|
10kv HRYJ-1/1 | 10kV cross-linked cable heat shrinkable cable joint (single-conductor) |
25-50 |
10kv HRYJ-1/2 |
70-120 |
|
10kv HRYJ-1/3 |
150-240 |
|
10kv HRYJ-1/4 |
300-400 |
|
10kv HRYN-3/1 | 10kV cross-linked cable heat shrinkable indoor termination (three-conductor) |
25-50 |
10kv HRYN-3/2 |
70-120 |
|
10kv HRYN-3/3 |
150-240 |
|
10kv HRYN-3/4 |
300-400 |
|
10kv HRYW-3/1 | 10kV cross-linked cable heat shrinkable outdoor termination (three-conductor) |
25-50 |
10kv HRYW-3/2 |
70-120 |
|
10kv HRYW-3/3 |
150-240 |
|
10kv HRYW-3/4 |
300-400 |
|
10kv HRYJ-3/1 | 10kV cross-linked cable heat shrinkable cable joint (three-conductor) |
25-50 |
10kv HRYJ-3/2 |
70-120 |
|
10kv HRYJ-3/3 |
150-240 |
|
10kv HRYJ-3/4 |
300-400 |
|
35kv HRYN-1/1 | 35kV cross-linked cable heat shrinkable indoor termination (single-conductor) |
50-95 |
35kv HRYN-1/2 |
120-185 |
|
35kv HRYN-1/3 |
240-400 |
|
35kv HRYW-1/1 | 35kV cross-linked cable heat shrinkable outdoor termination (single-conductor) |
50-95 |
35kv HRYW-1/2 |
120-185 |
|
35kv HRYW-1/3 |
240-400 |
|
35kv HRYJ-1/1 | 35kV cross-linked cable heat shrinkable cable joint (single-conductor) |
50-95 |
35kv HRYJ-1/2 |
120-185 |
|
35kv HRYJ-1/3 |
240-400 |
|
35kv HRYN-3/1 | 35kV cross-linked cable heat shrinkable indoor termination (three-conductor) |
50-95 |
35kv HRYN-3/2 |
120-185 |
|
35kv HRYN-3/3 |
240-400 |
|
35kv HRYW-3/1 | 35kV cross-linked cable heat shrinkable outdoor termination (three-conductor) |
50-95 |
35kv HRYW-3/2 |
120-185 |
|
35kv HRYW-3/3 |
240-400 |
|
35kv HRYJ-3/1 | 35kV cross-linked cable heat shrinkable cable joint (three-conductor) |
50-95 |
35kv HRYJ-3/2 |
120-185 |
|
35kv HRYJ-3/3 |